3. Wiring
Wire the products as shown in the diagrams below. All switches are optional with presence detection, but a
switch will be required for absence detection. The dimming variants can have two switch configurations. If
used with Option A, a single momentary switch can be used for absence detection and dimming up/
downset switch mode 1 position switch together (see section 5). If used with Option B (the default
setting), a centre biased momentary switch gives the benefit of having separate switches to dim up and
downset switch mode 2 position switch together in this case. The DD-LCDHS programming handset will
be required to change the switch type if Option A is required for dimming applications.
MWS5
Non-dimming
MWS5-DD
MWS5-AD
Dimming
Switch Option B (Default)
MWS5-DD
MWS5-AD
Dimming
Switch Option A